Hunan Jinlian Cloud Information Technology Co., Ltd.

Manufacturer from China
Verified Supplier
1 Years
Home / Products / Column / Canister Load Cell /

Ultimate Overload 300% F.S SC4810 200T 300T 400T 1000T 4 Column Load Cell for Piling Building Foundation Test mV/V Output

Contact Now
Hunan Jinlian Cloud Information Technology Co., Ltd.
Visit Website
City:changsha
Province/State:hunan
Country/Region:china
Contact Person:MrJason Zhu
Contact Now

Ultimate Overload 300% F.S SC4810 200T 300T 400T 1000T 4 Column Load Cell for Piling Building Foundation Test mV/V Output

Ask Latest Price
Video Channel
Series :column load cell
Features :heavy duty 300t 500t load cell
Mounting Type :screw installation
Description :1000t load cell for piling, SC4810 load cell
Model Number :SC4810
Type :Load Cell
Place of Origin :Guangdong, China
Brand Name :SNC
Use :Force measurement
Theory :Convert force into electrical signal
Output :mV/V
Model :SC4810
Material :Alloy Steel
Capacity :30T, 50T, 100T, 200T, 300T, 500T,1000T
Accuracy class :0.03%F.S
rated output :2.0±0.04mV/V
Combined error :≤±0.030 % F.S
Zero balance :±1.0 %F.S
Ultimate overload :300% F.S
IP grade :IP67
Application :hydraulic machine, hydraulic jack, test pile
Price :$130-1,650/units
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

SC4810 200T 300T 400T 1000T 4 Column Load Cell For Piling Building Foundation Test

Ultimate Overload 300% F.S SC4810 200T 300T 400T 1000T 4 Column Load Cell for Piling Building Foundation Test mV/V Output

Features:

1, Material: Alloy steel with IP66/ IP67 waterproof.

2, Application: hydraulic jack,Truck and railway scales, tank and silo weighing and in heavy duty industrial scales.
3, Optional accessories: Indicator / display, junction box.

Parameters:

Application hydraulic jack
Model SC4810
Capacity 500T, 600T, 700T, 1000T
rated output 2.0±0.004mV/V
Accuracy class C2 C3
maximum number of verification intervals 2000 Nmax 3000 Nmax
Minimum loadcell cerification intervals Emax/5000Vmin Emax7500 Vmin
Combined error ≤±0.030 % RO ≤±0.020 % RO
Creep 0.026 %RO/30min 0.018 %RO/30min
Temp. effect on sensitivity 0.0015 %RO/℃
Temp.effect on zero 0.0026%RO/℃ 0.0018%RO/℃
Zero balance ±1.0 %RO
Input resistance 670±10 ohm 1050±10 ohm
Output resistance 605±5 ohm 1000±5 ohm
insulation resistance 5000 MΩ(50V)
Recommended excitation voltage 10-18V
Compensated temperature range -10-+40℃
operating temperature range -35-+80 ℃
safe overload 150 %RO
Ultimate overload 300%RO
loadcell material Alloy steel stainless steel
Connecting cable 10-30T Φ6.3x13m 40-300T Φ6.3x20m
Method of connecting wire Red- input+, black- Input-. Green- Output+, White- output -

Size: mm

Ultimate Overload 300% F.S SC4810 200T 300T 400T 1000T 4 Column Load Cell for Piling Building Foundation Test mV/V Output

Ultimate Overload 300% F.S SC4810 200T 300T 400T 1000T 4 Column Load Cell for Piling Building Foundation Test mV/V OutputUltimate Overload 300% F.S SC4810 200T 300T 400T 1000T 4 Column Load Cell for Piling Building Foundation Test mV/V OutputUltimate Overload 300% F.S SC4810 200T 300T 400T 1000T 4 Column Load Cell for Piling Building Foundation Test mV/V OutputUltimate Overload 300% F.S SC4810 200T 300T 400T 1000T 4 Column Load Cell for Piling Building Foundation Test mV/V Output

Accessories

Ultimate Overload 300% F.S SC4810 200T 300T 400T 1000T 4 Column Load Cell for Piling Building Foundation Test mV/V Output

Ultimate Overload 300% F.S SC4810 200T 300T 400T 1000T 4 Column Load Cell for Piling Building Foundation Test mV/V Output

Related Products

Ultimate Overload 300% F.S SC4810 200T 300T 400T 1000T 4 Column Load Cell for Piling Building Foundation Test mV/V Output
Company Information

Sensor and Control Co., Ltd. was founded in 2006, mainly engaged in Torque Sensor, Load Cell, Pressure Transducer, Strain Gauges and Weighing Indicators. Since establishment, we insist the guidelines of "Customer Oriented, Quality Focused, Professional Service "All products we supply are environment friendly and has passed RoHS test.

Sensorcon, in accordance with the principle of the introduction of advanced professional ultrasonic gas cleaning, clean Room patches, automatic temperature compensation and detection, high and low temperature testing and thermal experiments, laser welding and printing, CAD design, manufacturing and testing sensor test equipment and production technology ,manufacture all varieties of sensors, high precision, stable performance and also has antiseptic, waterproof, anti-explosion, anti-lightning, etc favored deeply by users.

Ultimate Overload 300% F.S SC4810 200T 300T 400T 1000T 4 Column Load Cell for Piling Building Foundation Test mV/V Output

Ultimate Overload 300% F.S SC4810 200T 300T 400T 1000T 4 Column Load Cell for Piling Building Foundation Test mV/V Output

Packaging & Shipping

Ultimate Overload 300% F.S SC4810 200T 300T 400T 1000T 4 Column Load Cell for Piling Building Foundation Test mV/V Output

FAQ

1.How to place an order ?
Please provide us more details of what you want, such as: application, measurement range, output, accuracy, thread type, electric connector and other related parameters.

2.Does SNCoffer any discount ?
Yes, if you buy large QTY, please contact us, we will give you a big discount.

3.What terms of payment are available ?
We accept T/T, L/C, Trade assurance, Western Union, Paypal, etc.

4.When will you arrange the production ?
We will arrange the production immediately after receiving your payment.

5.How do you ensure good product quality ?
We have a complete quality control system, all of our products are fully checked by IQC, OQC departments

before shipping to our clients.

6.Do you have warranty ?
Yes, we provide 1 year warranty for most of our products. Some products we offer 15month to 24 months warranty.

Contact Us

Ultimate Overload 300% F.S SC4810 200T 300T 400T 1000T 4 Column Load Cell for Piling Building Foundation Test mV/V OutputSC4810 200T 300T 400T 1000T 4 Column Load Cell For Piling Building Foundation Test

SC4810 200T 300T 400T 1000T 4 Column Load Cell For Piling Building Foundation Test

SC4810 200T 300T 400T 1000T 4 Column Load Cell For Piling Building Foundation Test

Inquiry Cart 0