Hunan Jinlian Cloud Information Technology Co., Ltd.

Manufacturer from China
Verified Supplier
1 Years
Home / Products / Weight Control indicator /

Load Cell Digital Amplifier with RS485 Output 145/115x80x46mm Size and Customized Support Software Reengineering

Contact Now
Hunan Jinlian Cloud Information Technology Co., Ltd.
Visit Website
City:changsha
Province/State:hunan
Country/Region:china
Contact Person:MrJason Zhu
Contact Now

Load Cell Digital Amplifier with RS485 Output 145/115x80x46mm Size and Customized Support Software Reengineering

Ask Latest Price
Video Channel
warranty :1 years
customized support :OEM, ODM, OBM, Software reengineering
place of origin :Guangdong, China
brand name :SNC China Load cell amplifier transmitter
accuracy :Other
model number :amplifier transmitter
type :Axle Scale
display type :no
Name :4-20mA amplifier transmitter
Material :plastic housing
Voltage :24VDC
Output signal :RS485
Working temperature :-20~80 ℃
Precision :more than 0.1%F.S
Display :metal case support
Size :145/115x80x46mm
load cell connection :1- 4 load cells
working temp. :-10--70 degree
Price :$80/pieces
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Load cell digital amplifier RS485 output

Load Cell Digital Amplifier with RS485 Output 145/115x80x46mm Size and Customized Support Software Reengineering

Voltage: 10V

Output signal: 0-5V, 0-10V, 4-20mA (Optional)

Working temperature: -20~80

Working environment Humidity: 10%RH-90%RH

Precision: more than 0.1%F.S

China Load cell amplifier transmitter

Load Cell Digital Amplifier with RS485 Output 145/115x80x46mm Size and Customized Support Software Reengineering

Calibration:

First, with the whole system UNLOADED, adjust "ZERO" potentiometer to adjust the zero offset.

Measure the output voltage or current of signal output with multimeter, make sure the value is as close to

zero as possible. Otherwise zero variation will get bigger when we change gain factor.

1, Gain adjustment

Add known load to the system (recommend: 80%~100% of Full Scale), then calculate value of the

output voltage or current according to the ratio between loaded weight and the maximum capacity.

Get output value using a multimeter. Adjust amplifier gain by turning "FULL SCALE" potentiometer.

2, Review

Unload the system and measure zero output. Make sure that it is as close as possible to zero.

Add known load, check whether the output voltage or current is amplified as needed you wanted or not.

If not, repeat steps 1 and 2.

(Note: this section is for standard sensor amplifier parameters. For special requirements, please

contact our sales department)

Product Description

Sensorcon Product Lists
Strain Gauge Load Cell Torque Sensor Display
Linear Strain gauge-AA Wireless sensor Slip ring rotary torque sensor Platform scale display
Half bridge strain gauge-BB,HA,GB,FB Micro load cell Contactless rotary torque sensor Truck scale display
Shear/torque strain gauge-AB,HA Single point load cell Static torque sensor Controller
Full bridge strain gauge-EB, FG,FD Button load cell Meters Junction box
Tee Rosettes strain gauge-CA,BA Shear beam load cell Coupling Big screen display
Round type strain gauge S type load cell Amplifier
Semi-conductor strain gauge Column load cell
Bridge type load cell

Company Information

Sensor and Control Co., Ltd. was founded in 2006, mainly engaged in Torque Sensor, Load Cell, Pressure Transducer, Strain Gauges and Weighing Indicators. Since establishment, we insist the guidelines of "Customer Oriented, Quality Focused, Professional Service "All products we supply are environment friendly and has passed RoHS test.

Sensorcon, in accordance with the principle of the introduction of advanced professional ultrasonic gas cleaning, clean Room patches, automatic temperature compensation and detection, high and low temperature testing and thermal experiments, laser welding and printing, CAD design, manufacturing and testing sensor test equipment and production technology ,manufacture all varieties of sensors, high precision, stable performance and also has antiseptic, waterproof, anti-explosion, anti-lightning, etc favored deeply by users.

Load Cell Digital Amplifier with RS485 Output 145/115x80x46mm Size and Customized Support Software Reengineering

Related Products

Load Cell Digital Amplifier with RS485 Output 145/115x80x46mm Size and Customized Support Software Reengineering Load Cell Digital Amplifier with RS485 Output 145/115x80x46mm Size and Customized Support Software Reengineering Load Cell Digital Amplifier with RS485 Output 145/115x80x46mm Size and Customized Support Software Reengineering
Load Cell Digital Amplifier with RS485 Output 145/115x80x46mm Size and Customized Support Software Reengineering Load Cell Digital Amplifier with RS485 Output 145/115x80x46mm Size and Customized Support Software Reengineering Load Cell Digital Amplifier with RS485 Output 145/115x80x46mm Size and Customized Support Software Reengineering
Load Cell Digital Amplifier with RS485 Output 145/115x80x46mm Size and Customized Support Software Reengineering Load Cell Digital Amplifier with RS485 Output 145/115x80x46mm Size and Customized Support Software Reengineering Load Cell Digital Amplifier with RS485 Output 145/115x80x46mm Size and Customized Support Software Reengineering

Product List

Sensorcon Product Lists
Strain Gauge Load Cell Torque Sensor Display
Linear Strain gauge-AA Wireless sensor Slip ring rotary torque sensor Platform scale display
Half bridge strain gauge-BB,HA,GB,FB Micro load cell Contactless rotary torque sensor Truck scale display
Shear/torque strain gauge-AB,HA Single point load cell Static torque sensor Controller
Full bridge strain gauge-EB, FG,FD Button load cell Meters Junction box
Tee Rosettes strain gauge-CA,BA Shear beam load cell Coupling Big screen display
Round type strain gauge S type load cell Amplifier
Semi-conductor strain gauge Column load cell
Bridge type load cell
Buying Guides

Load Cell Digital Amplifier with RS485 Output 145/115x80x46mm Size and Customized Support Software Reengineering

Inquiry Cart 0